Capacitive Sensors – Part III

Written by: Bjoern Schaefer

Typical Dielectric Material Factors

Typical Dielectric Material Factors

The general sensing principle across this myriad of applications is nearly the same. As seen in last months post, the total amount of capacitance, as we remember, the ability to store a charge within an electrostatic field, depends on mainly three factors. Those factors are the ones which determine the success of your application.

1.  The size of the electrode area
A larger electrode will cause a larger and deeper field. Therefore, larger capacitive proximity sensors offer a longer sensing range as smaller ones.

2.  Distance between electrodes
The larger the distance, the smaller the capacitance – capacitive proximity sensors have usually maximum sensing distances of up to 30mm.

3.  Dielectric material factor
The dielectric factor is material specific and is probably the most important variable in your capacitive application. The table below shows typically dielectric values for common liquids and materials. A higher value indicates a higher capacitance given that all other variables stay constant.

Given these three variables, capacitive sensors can perform a variety of tasks:

Proximity – Sensor area and target material stay constant, the sensor will provide changing signal depending on the distance to the target.

Material composition – Sensor area and distance stay constant while the materials dielectric factor changes. This would allow the sensor to differentiate for example between two or more plastic materials of same color and shape.

Indirect sensing – Keeping again the sensor area and distance constant, capacitive sensors are capable to sense material through other materials. For example detect water through a non-metallic glass or plastic wall. This is possible, as long as the wall material has a lower or equal dielectric constant as the target.

In the next part, we will look at possible problems you have to be aware of when using capacitive sensing technology.

Previous posts:
Capacitive Sensors – Part I
See Capacitive Sensors – Part II

This entry was posted in All posts, Capacitive Sensors and tagged , , , , , . Bookmark the permalink.

What do you think?

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s